Brand Name: HX
Model Number: HX-PE-90-Z
MOQ: 2000 PCS
Price: negotiatiable
Delivery Time: 15-20 Days upon 20GP
Payment Terms: L/C, T/T
Detail Information
Place of Origin:
YUYAO CHINA
Certification:
UL 514B E345464, ISO9001, SGS
Material:
Zinc Alloy ZAMAK 3 Die Casting
Cover Type:
Removable With Neoprene Gasket
Size Range:
1/2 Inch To 4 Inch Set-Screw
Angle:
90 Degrees
Environmental Rating:
NEMA 4 Watertight Concrete-Tight
Voltage Rating:
Suitable Above 600V
Packaging Details:
Individual polybag plus partitioned export carton with pallet, project kitting available
Supply Ability:
200 Ton per Month
Highlight:

EMT Pull Elbow 90 degree conduit fitting

,

Waterproof conduit body UL listed

,

1/2 to 4 inch EMT pulling solution

Product Description

HX EMT 90-Degree Pull Elbow Access Fittings provide accessible pulling points at every directional change in conduit raceway systems. Removable gasketed cover plate with NEMA 4 waterproof rating. Zinc alloy ZAMAK 3 die-cast. Set-screw EMT connections on both ends. Complete size range from 1/2 inch to 4 inch. 27 years. UL E345464. ISO9001.

EMT Pull Elbow 90 Degree Access Fitting with Removable Cover
90°Pull Angle
NEMA 4Waterproof
600V+Voltage Rated
9Sizes 1/2-4"
-60%Pull Tension
ConcreteTight Rated
Jobsite Pain Points & HX Solutions
PAIN POINT: Excessive Pulling Tension Damages Conductors
Pulling through a standard 90-degree elbow without access creates friction hot spots. Insulation stretches, thins, and fails megohmmeter testing. Result: pull out the damaged conductors and start over. Cost: US$850+ in labor and materials per failed pull.
HX SOLUTION: Full-Access Pulling Chamber
Removable cover plate provides full access to the interior raceway at the bend point. Electricians grip conductors directly at the direction change, reducing pulling tension by up to 60%. Zero insulation damage. Passes megohmmeter on the first attempt.
PAIN POINT: Water Ingress in Outdoor and Wet-Location Pull Points
Standard pull elbows without gaskets allow moisture infiltration in parking garages, outdoor equipment pads, and wastewater facilities. Corrosion inside the raceway damages conductors over time and creates intermittent ground faults.
HX SOLUTION: NEMA 4 Watertight Sealing
Neoprene gasket between body and cover plate achieves NEMA 4 watertight, raintight, and oiltight ratings. Submersion-tested in production QC. Suitable for wet locations, outdoor installations, and concrete-embedded applications.
PAIN POINT: Oversized Conduit Bodies for NEC Fill Compliance
Cheap pull elbows have undersized interior cavities. To meet NEC Chapter 9 conduit body fill requirements, contractors must oversize to the next trade size, increasing material cost by 40-60%.
HX SOLUTION: NEC-Optimized Interior Volume
Generously proportioned interior cavity meets NEC conduit body fill requirements for standard conductor sizes and quantities at the nominal trade size. No oversizing required. No special engineering calculations. Code compliant as-specified.
One Fitting, Five Certifications: UL 514B Listed (E345464) | NEMA 4 Watertight | Concrete-Tight Rated | Raintight | Oiltight
Suitable for applications above 600V. Full documentation package included with every shipment.
Technical Specifications
ParameterSpecification
Body & CoverZinc Alloy ZAMAK 3 High-Pressure Die Casting
Cover SealNeoprene Gasket, Captive Design
Trade Sizes1/2, 3/4, 1, 1-1/4, 1-1/2, 2, 2-1/2, 3, 4 inch
Conduit ConnectionSet-Screw EMT Slip Fit, Both Ends
Cover FastenersCombo Head Steel Screws (Slotted / Phillips / Robertson)
Angle90 Degrees Nominal
Environmental RatingsNEMA 4 Watertight, Raintight, Oiltight, Concrete-Tight
CertificationsUL 514B Listed (E345464), ISO9001:2015, SGS
Voltage RatingSuitable for Applications Above 600V
Temperature Range-40 deg C to 120 deg C
Conduit CompatibilityEMT Thinwall, IMC, Rigid (Sizes 2-1/2 to 4 inch)
MOQ2,000 PCS per Size
Lead Time15-20 Days per 20GP Container
PortNingbo or Shanghai, China
Key Features
  • Full-Access Pulling Chamber — Removable gasketed cover provides complete access at the 90-degree bend. Reduces pulling tension by up to 60%. Eliminates conductor insulation damage.
  • NEMA 4 Multi-Rating — Watertight, raintight, oiltight, and concrete-tight. One fitting covers indoor, outdoor, and embedded applications.
  • NEC-Optimized Cavity Volume — Interior dimensions meet Chapter 9 conduit body fill requirements at nominal trade size. No oversizing needed.
  • Combo Head Cover Screws — Same tri-drive design across the entire HX fitting product line. One screwdriver handles all installation fasteners.
  • UL Listed Above 600V — Suitable for medium-voltage industrial power distribution beyond standard commercial building voltages.
Installation Scenarios
  • High-Rise Electrical Risers — Pull floor-by-floor at horizontal-to-vertical transitions instead of attempting continuous multi-story pulls
  • Industrial Overhead Conduit Racks — Provide pulling access where lighting and equipment circuits navigate around structural steel and HVAC ductwork
  • Hospital Critical Branch Circuits — Maintain accessible pulling points for future circuit modifications in operating room and ICU power distribution
  • Data Center Feeder Distribution — Keep pulling tension within manufacturer limits for large-gauge conductors at cable tray transition points
  • Water Treatment Plants — NEMA 4 watertight construction for pump station and outdoor chemical feed equipment power circuits
  • Cast-in-Place Concrete Slabs — Flush-mounted accessible cover remains serviceable after concrete pour for long-term maintenance access
Packaging & OEM

Individual polybag protection with body and cover packaged together. Foam cell dividers in master cartons prevent surface scratching. Project kitting available: pre-labeled cartons organized by floor, zone, or electrical room per contractor schedule. OEM private-label options: custom carton printing, branded inserts, QR-coded installation guides. 12-month defect warranty. Free replacement for quality non-conformance.

Good price online

Products Details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
Electrical Conduit Fittings
Created with Pixso. EMT Pull Elbow 90 Degree Access Fitting Waterproof Conduit Body 1/2 to 4 Inch UL Listed Pulling Solution

EMT Pull Elbow 90 Degree Access Fitting Waterproof Conduit Body 1/2 to 4 Inch UL Listed Pulling Solution

Brand Name: HX
Model Number: HX-PE-90-Z
MOQ: 2000 PCS
Price: negotiatiable
Packaging Details: Individual polybag plus partitioned export carton with pallet, project kitting available
Payment Terms: L/C, T/T
Detail Information
Place of Origin:
YUYAO CHINA
Brand Name:
HX
Certification:
UL 514B E345464, ISO9001, SGS
Model Number:
HX-PE-90-Z
Material:
Zinc Alloy ZAMAK 3 Die Casting
Cover Type:
Removable With Neoprene Gasket
Size Range:
1/2 Inch To 4 Inch Set-Screw
Angle:
90 Degrees
Environmental Rating:
NEMA 4 Watertight Concrete-Tight
Voltage Rating:
Suitable Above 600V
Minimum Order Quantity:
2000 PCS
Price:
negotiatiable
Packaging Details:
Individual polybag plus partitioned export carton with pallet, project kitting available
Delivery Time:
15-20 Days upon 20GP
Payment Terms:
L/C, T/T
Supply Ability:
200 Ton per Month
Highlight:

EMT Pull Elbow 90 degree conduit fitting

,

Waterproof conduit body UL listed

,

1/2 to 4 inch EMT pulling solution

Product Description

HX EMT 90-Degree Pull Elbow Access Fittings provide accessible pulling points at every directional change in conduit raceway systems. Removable gasketed cover plate with NEMA 4 waterproof rating. Zinc alloy ZAMAK 3 die-cast. Set-screw EMT connections on both ends. Complete size range from 1/2 inch to 4 inch. 27 years. UL E345464. ISO9001.

EMT Pull Elbow 90 Degree Access Fitting with Removable Cover
90°Pull Angle
NEMA 4Waterproof
600V+Voltage Rated
9Sizes 1/2-4"
-60%Pull Tension
ConcreteTight Rated
Jobsite Pain Points & HX Solutions
PAIN POINT: Excessive Pulling Tension Damages Conductors
Pulling through a standard 90-degree elbow without access creates friction hot spots. Insulation stretches, thins, and fails megohmmeter testing. Result: pull out the damaged conductors and start over. Cost: US$850+ in labor and materials per failed pull.
HX SOLUTION: Full-Access Pulling Chamber
Removable cover plate provides full access to the interior raceway at the bend point. Electricians grip conductors directly at the direction change, reducing pulling tension by up to 60%. Zero insulation damage. Passes megohmmeter on the first attempt.
PAIN POINT: Water Ingress in Outdoor and Wet-Location Pull Points
Standard pull elbows without gaskets allow moisture infiltration in parking garages, outdoor equipment pads, and wastewater facilities. Corrosion inside the raceway damages conductors over time and creates intermittent ground faults.
HX SOLUTION: NEMA 4 Watertight Sealing
Neoprene gasket between body and cover plate achieves NEMA 4 watertight, raintight, and oiltight ratings. Submersion-tested in production QC. Suitable for wet locations, outdoor installations, and concrete-embedded applications.
PAIN POINT: Oversized Conduit Bodies for NEC Fill Compliance
Cheap pull elbows have undersized interior cavities. To meet NEC Chapter 9 conduit body fill requirements, contractors must oversize to the next trade size, increasing material cost by 40-60%.
HX SOLUTION: NEC-Optimized Interior Volume
Generously proportioned interior cavity meets NEC conduit body fill requirements for standard conductor sizes and quantities at the nominal trade size. No oversizing required. No special engineering calculations. Code compliant as-specified.
One Fitting, Five Certifications: UL 514B Listed (E345464) | NEMA 4 Watertight | Concrete-Tight Rated | Raintight | Oiltight
Suitable for applications above 600V. Full documentation package included with every shipment.
Technical Specifications
ParameterSpecification
Body & CoverZinc Alloy ZAMAK 3 High-Pressure Die Casting
Cover SealNeoprene Gasket, Captive Design
Trade Sizes1/2, 3/4, 1, 1-1/4, 1-1/2, 2, 2-1/2, 3, 4 inch
Conduit ConnectionSet-Screw EMT Slip Fit, Both Ends
Cover FastenersCombo Head Steel Screws (Slotted / Phillips / Robertson)
Angle90 Degrees Nominal
Environmental RatingsNEMA 4 Watertight, Raintight, Oiltight, Concrete-Tight
CertificationsUL 514B Listed (E345464), ISO9001:2015, SGS
Voltage RatingSuitable for Applications Above 600V
Temperature Range-40 deg C to 120 deg C
Conduit CompatibilityEMT Thinwall, IMC, Rigid (Sizes 2-1/2 to 4 inch)
MOQ2,000 PCS per Size
Lead Time15-20 Days per 20GP Container
PortNingbo or Shanghai, China
Key Features
  • Full-Access Pulling Chamber — Removable gasketed cover provides complete access at the 90-degree bend. Reduces pulling tension by up to 60%. Eliminates conductor insulation damage.
  • NEMA 4 Multi-Rating — Watertight, raintight, oiltight, and concrete-tight. One fitting covers indoor, outdoor, and embedded applications.
  • NEC-Optimized Cavity Volume — Interior dimensions meet Chapter 9 conduit body fill requirements at nominal trade size. No oversizing needed.
  • Combo Head Cover Screws — Same tri-drive design across the entire HX fitting product line. One screwdriver handles all installation fasteners.
  • UL Listed Above 600V — Suitable for medium-voltage industrial power distribution beyond standard commercial building voltages.
Installation Scenarios
  • High-Rise Electrical Risers — Pull floor-by-floor at horizontal-to-vertical transitions instead of attempting continuous multi-story pulls
  • Industrial Overhead Conduit Racks — Provide pulling access where lighting and equipment circuits navigate around structural steel and HVAC ductwork
  • Hospital Critical Branch Circuits — Maintain accessible pulling points for future circuit modifications in operating room and ICU power distribution
  • Data Center Feeder Distribution — Keep pulling tension within manufacturer limits for large-gauge conductors at cable tray transition points
  • Water Treatment Plants — NEMA 4 watertight construction for pump station and outdoor chemical feed equipment power circuits
  • Cast-in-Place Concrete Slabs — Flush-mounted accessible cover remains serviceable after concrete pour for long-term maintenance access
Packaging & OEM

Individual polybag protection with body and cover packaged together. Foam cell dividers in master cartons prevent surface scratching. Project kitting available: pre-labeled cartons organized by floor, zone, or electrical room per contractor schedule. OEM private-label options: custom carton printing, branded inserts, QR-coded installation guides. 12-month defect warranty. Free replacement for quality non-conformance.